{"L_end_H": null, "required_for_physical_end_model": ["end winding geometry and connections", "material and support geometry", "3D or justified additional cross sections", "end inductance/loss validation"], "base_U_line_V": 19999.86701209983, "factory_terminal_voltage_claim": false, "dU_line_dL_end_V_per_H": -2919278.2619462507, "dP_generator_dL_end_W_per_H": 0.0, "dQ_generator_dL_end_var_per_H": -97835065336.70639, "fixed_conditions": "fixed id, iq, If and active-section field; derivative at explicitly excluded Lend=0"}